澳门威尼斯人注册网址【官网首页】
做最好的网站

Windows-WMI 事件 ID 10或0x80041003 死机 解药

来源:http://www.ogcoffee123.com 作者:操作系统 人气:77 发布时间:2019-11-06
摘要:      ChannelApplication/Channel     Opcode0/Opcode obj2.Delete_ T   obj3.Delete_ 事件 Xml:     TimeCreated SystemTime="2017-11-11T14:08:41.000000000Z" / 日期:            2017-11-11 22:08:41 文件转语音功用只限200个

 

    <Channel>Application</Channel>

    <Opcode>0</Opcode>

obj2.Delete_

T

 

obj3.Delete_

事件 Xml:


    <TimeCreated SystemTime="2017-11-11T14:08:41.000000000Z" />

日期:            2017-11-11 22:08:41

文件转语音功用只限200个字符

For Each obj1elem in obj1

WScript.echo "Deleting the object"

    <Computer>longware-T430</Computer>

级别:            错误

    <Task>0</Task>

关键字:           经典

事件 ID:         10

</Event>

 大惑不解,于是乎google,开采本国的帖子还木有,海外有多少个缓慢解决办法,内容如下。


    <Keywords>0x80000000000000</Keywords>

    <Data>SELECT * FROM __InstanceModificationEvent WITHIN 60 WHERE TargetInstance ISA "Win32_Processor" AND TargetInstance.LoadPercentage > 99</Data>

    <Version>0</Version>

    <Provider Name="Microsoft-Windows-WMI" Guid="{1edeee53-0afe-4609-b846-d8c0b2075b1f}" EventSourceName="WinMgmt" />

next

 最近木有现身死机,是或不是深透淹没,景象后效。

<Event xmlns=";

 

 

WScript.echo obj3.GetObjectText_

WScript.echo "Deleting the object"

    <Correlation />

strComputer = "."

来源:            Microsoft-Windows-WMI

描述:

职分项目:          无

For each obj3 in obj3set

 

选项 : 历史 : 反馈 : Donate 关闭

 

set obj2set = obj1elem.Associators_("__FilterToConsumerBinding")

WScript.echo "Deleting the object"

  <System>

新兴在平安格局里查了风云,如下 

& "{impersonationLevel=impersonate}!\" _

    <Data>//./root/CIMV2</Data>

    <EventRecordID>93359</EventRecordID>

    <Data>0x80041003</Data>

中文简体俄语日语英语韩语
中文简体俄语日语英语韩语

Set objWMIService = GetObject("winmgmts:" _

Event filter with query "SELECT * FROM __InstanceModificationEvent WITHIN 60 WHERE TargetInstance ISA "Win32_Processor" AND TargetInstance.LoadPercentage > 99" could not be reactivated in namespace "//./root/CIMV2" because of error 0x80041003. Events cannot be delivered through this filter until the problem is corrected.

next

日记名称:          Application

  <EventData>

    <Level>2</Level>

备忘之。

  </EventData>

Set obj1 = objWMIService.ExecQuery("select * from __eventfilter where name='BVTFilter' and query='SELECT * FROM __InstanceModificationEvent WITHIN 60 WHERE TargetInstance ISA ""Win32_Processor"" AND TargetInstance.LoadPercentage > 99'")

用户:            暂缺

  </System>

WScript.echo obj1elem.GetObjectText_

For each obj2 in obj2set

obj1elem.Delete_

Next

创立一个 test.vbs 文件,贴入如下内容,保存,然后以管理人格局运作cmd,在cmd里进行test.vbs

最近几年台式机重复了某个次意外的现象,重启后走入桌面,然后死机,木有蓝屏。

G

WScript.echo obj2.GetObjectText_

set obj3set = obj1elem.References_("__FilterToConsumerBinding")

 

M

计算机:           longware-T430

& strComputer & "rootsubscription")

    <EventID Qualifiers="49152">10</EventID>

    <Security />

    <Execution ProcessID="0" ThreadID="0" />

本文由澳门威尼斯人注册网址发布于操作系统,转载请注明出处:Windows-WMI 事件 ID 10或0x80041003 死机 解药

关键词:

上一篇:没有了

下一篇:用CRT查找内存泄漏